Variable waveguide attenuators are found in many applications including test setups and various electronic systems. Attenuators employing active devices vary their attenuation in response to electronic control signals. Passive Level-Setting attenuators are adjusted mechanically. They do not display the attenuation level directly. Instead, they provide a micrometer reading that can be used with calibration data to estimate attenuation. Direct Reading rotary vane attenuators offer superior frequency responses and show the attenuation setting on a numerical scale or a digital display. Motorized rotary vane attenuators allow remote control, while newer Hybrid designs combine the functions of Direct Reading and Programmable attenuators in a single unit.
A typical active attenuator uses one or more PIN diodes to provide variable impedances inside the waveguide (Fig. 1). They offer excellent repeatability, wide dynamic range, and fast response times. However they often have poor return-loss performance at high attenuation levels. Their insertion loss and isolation are also limited when they are compared to their counterparts, passive waveguide attenuators.
Fig. 1 – PIN diode attenuators support electronic control with fast response times, but their return loss may be poor at high attenuation levels.
A common type of passive waveguide attenuator, known as an E-plane attenuator, has an absorbing or lossy device placed inside a rectangular waveguide (Fig. 2). A resistive material in the form of a thin card or vane dissipates a fraction of the applied signal. The operating mode of the attenuator is TE10 and the absorbing vane is oriented for maximum coupling with the electric field inside the waveguide. The vane is tapered to minimize reflections.
Fig. 2 – A schematic view of an E-plane attenuator shows an absorbing vane penetrating the waveguide through a slot. Variable attenuators allow adjustment of the vane position.
Variable E-plane attenuators allow adjustment of the vane position inside the waveguide. A micrometer head precisely controls how far the absorbing vane penetrates a slot in the waveguide wall (Fig. 3). The micrometer reading can be used with calibration data to estimate the attenuation value. Such designs are known as Level Setting attenuators. They are effective and economical choices for applications where signal levels are set using a spectrum analyzer or an amplitude detector while the attenuator is adjusted. This type of attenuator has a frequency-dependent response due to its mechanical configuration and the electrical properties of the vane material. For a given amount of vane insertion into the waveguide, attenuation is less at the low end of the operating frequency band compared to the high end. The frequency dependence is worse for higher attenuation levels.
Fig. 3 – A level-setting attenuator includes a micrometer head for precise adjustments.
A more advanced type of variable attenuator uses a rotary vane for the absorbing device (Fig. 4). The vane is mounted inside a circular waveguide section that supports the TE11 propagation mode. For rectangular waveguide interface purposes, rectangular-to-circular mode transitions are connected at both ends of the circular waveguide. An adjustment mechanism rotates the circular waveguide section to vary the orientation of the vane. The vane fully absorbs the vector component of the electric field that is parallel to the vane. The vane has a negligible effect on the perpendicular field component. The electric field that passes the vane is reduced in magnitude by a factor equal to the cosine of theta, where theta is the angular displacement between the incident electric field and a normal vector emanating from the vane. The orientation of the remaining electric field is perpendicular to the vane. Because of this orientation, a portion of the electric field is blocked by the mode transition on the output port and the electric field is again reduced by the cosine of theta. Total attenuation of the electric field follows the cosine-squared theta law. The attenuation mechanism is independent of the signal frequency, resulting in a flat frequency response over a wide bandwidth.
Fig. 4 – A rotary vane attenuator varies the orientation of an absorbing vane.
For attenuation levels up to 40 dB or more, excellent accuracy and repeatability are achieved. Because of this unique feature, rotary vane attenuators can be constructed with direct-reading indicators. They have a nearly flat frequency response with superior return loss performance when compared to typical E-plane attenuators.
Fig. 5 – Traditional direct-reading rotary vane attenuators include a cylindrical scale that indicates the attenuation value.
A traditional rotary vane attenuator includes an adjustment dial and a numerical scale that displays the attenuation value directly (Fig. 5). Such attenuators are commonly known as Direct Reading variable attenuators. As an alternative to a numerical scale, electronic circuitry may be used to monitor the vane position and show the attenuation value on a digital display (Fig. 6). The digital readout is less costly to manufacture and provides greater resolution than a numerical scale. The traditional dial provides a familiar adjustment mechanism, and an internal battery supports cordless operation.
Fig. 6 – Direct-reading attenuators may have a digital display instead of a mechanical scale.
Because they utilize complex mechanical components that are difficult to produce, rotary vane attenuators are considerably larger and more expensive than level setting E-plane attenuators. But their ability to directly indicate attenuation values and their superior frequency responses often justify their greater size and higher cost.
Programmable rotary vane attenuators use an internal motor to control the vane position in response to digital commands provided by a control system. Bench-top designs typically include a digital display and a user interface that enables manual adjustments, often with cumbersome menus and time-consuming adjustment procedures. Programmed operation is supported using a digital interface such as IEEE-488 or USB.
Hybrid programmable attenuators include a dial for easy manual adjustments (Fig. 7). The dial allows them to be used in place of traditional Direct Reading attenuators when programmable operation isn’t required. They are less costly than programmable attenuators, but more versatile than either direct reading or programmable attenuators that cover the same frequency range. As a result, Eravant has replaced its former offerings of traditional Direct Reading rotary vane attenuators and older-style Programmable attenuators with its newer Hybrid programmable attenuators.
Fig. 7 – A hybrid programmable rotary vane attenuator includes a dial for easy Direct Reading adjustments, as well as an internal motor and digital circuitry for automated control.